How many sockets per room? Minimums by country

Choose the room types and their sizes: the calculator applies the same room rules as the Circuia editor for your country (BS 7671 guidance and building regulations in the UK, NEC 210.52 spacing in the US, the national norm elsewhere) and shows the minimum sockets, lighting points and data outlets.

Updated on BS 7671 · NEC

Inputs

Rules applied: BS 7671:2018+A4:2026 — United Kingdom (beta, IET Wiring Regulations 18th Edition) · beta rules, to be checked locally

  • m²
  • m²
  • m²
  • m²
  • m²
  • m²
  • m²

Result

Sockets

0

Lights

0

RJ45

0

Minimum per room
RoomSocketsLightsRJ45
Living room 28 m²000
Kitchen 10 m²000
Bedroom 12 m²000
Bedroom 10 m²000
Bathroom 6 m²000
WC 1.5 m²000
Entrance hall 5 m²000

About 1 ring or radial socket circuit(s), each serving at most 100 m² of floor.

Minimums of the Circuia rules engine (BS 7671:2018+A4:2026 — United Kingdom (beta, IET Wiring Regulations 18th Edition)). Dedicated appliance outlets are not counted.

Estimate for planning only. Switch off before any work and have it checked by a qualified electrician.

Next step · free

Turn this result into a real plan

Open the editor with the Kitchen already drawn and its sockets placed: then wire it in one click.

Open the editor with this result →Free · no sign-up to start
</> Embed this tool on your website

Free, no sign-up. Paste this code into your page (blog, contractor site, forum): the tool shows up and stays up to date.

How it works

  • Each room is checked by the editor's rules engine for the selected country, as a real plan would be.
  • UK: socket recommendations of the IET On-Site Guide / building standards; ring final circuits up to 100 m² each (BS 7671 Appendix 15).
  • US: receptacles every 12 ft of wall (6 ft rule, NEC 210.52(A)) and countertop rules (210.52(C)).
  • Dedicated appliance outlets (washer, oven…) are not counted.

Frequently asked questions

How many double sockets should a bedroom have in the UK?

There is no single legal minimum in England; the usual guidance is several double sockets per bedroom (more in Scotland, where the building standards set numbers). The calculator shows the minimum Circuia applies for the selected country.

How far apart should receptacles be in the US?

NEC 210.52(A): no point along the floor line of a wall may be more than 6 ft from a receptacle, so one receptacle covers 12 ft of wall. Countertops: no point more than 24 in from a receptacle.

Are appliance sockets counted?

No. Dedicated outlets (washing machine, dishwasher, oven, cooker) come on top of the general-use sockets.

Design aid

For your actual home, move to the editor

Draw your home or describe it to the AI: Circuia places the points, checks the rules in real time and generates the consumer unit, single-line diagram and bill of materials.

Open the free editor

Other free tools