Consumer unit / panel planner

Describe the home (area, bedrooms, appliances): the editor's own auto-wiring builds the circuits, spreads them over RCDs (or RCBOs) for your country and sizes the consumer unit with its spare ways.

Updated on BS 7671 · NEC

Inputs

Rules applied: BS 7671:2018+A4:2026 — United Kingdom (beta, IET Wiring Regulations 18th Edition) · beta rules, to be checked locally

m²
Appliances
W

0 = no electric heating

Result

Rows

1

RCDs

6

Circuits

6

Type A (or F/B) RCDs6
Modules used18
With 0 % spare18 modules
  1. RCD 40 A 30 mA type A1/1

    • Cooker32 A · 6 mm²
  2. RCD 40 A 30 mA type A1/1

    • Water heater16 A · 2.5 mm²
  3. RCD 40 A 30 mA type A1/1

    • Lighting – living room, kitchen, bathroom +16 A · 1.5 mm²
  4. RCD 40 A 30 mA type A1/1

    • Lighting – hall, bedrooms6 A · 1.5 mm²
  5. RCD 40 A 30 mA type A1/1

    • Sockets – kitchen, bathroom32 A · 2.5 mm²
  6. RCD 40 A 30 mA type A1/1

    • Ventilation6 A · 1.5 mm²

Split computed by the Circuia wiring engine on a typical home (rows of 18 modules). Estimate to be checked by an electrician.

See the single-line diagram of this panel →

Estimate for planning only. Switch off before any work and have it checked by a qualified electrician.

Next step · free

Turn this result into a real plan

Draw your rooms, place sockets and lights: Circuia checks every rule as you go and builds the board schedule.

Open the free editor →Free · no sign-up to start
</> Embed this tool on your website

Free, no sign-up. Paste this code into your page (blog, contractor site, forum): the tool shows up and stays up to date.

How it works

  • A typical home is drawn with the minimum equipment of each room, then auto-wired as in the editor.
  • Circuits are spread over 30 mA RCDs with the country's limit per RCD, or one RCBO per circuit (UK, IE, CH).
  • Rows are counted with the country's module width and a spare-capacity margin.
  • US: branch circuits with GFCI / AFCI breakers where NEC 210.8 / 210.12 require them.

Frequently asked questions

How many RCDs does a house need?

It depends on the country: the UK splits circuits over at least two RCDs or uses RCBOs (BS 7671 314.1 to avoid unwanted tripping); most of Europe limits the number of circuits per RCD. The planner applies the selected country's rule.

RCBO or RCD board?

One RCBO per circuit means a fault only trips its own circuit. A dual-RCD board is cheaper but one trip cuts several circuits. Both can comply.

How many spare ways should I keep?

About 20 % spare ways is the usual rule for future circuits (EV charger, heat pump, solar).