Use case · Renovating a studio flat

Your studio flat's electrical plan, drawn online and checked against BS 7671

Renovating a 25–30 m² studio flat? Draw the main room, kitchenette and shower room in Circuia: the editor suggests sockets and lighting points, groups them into circuits behind 30 mA RCDs and flags anything that conflicts with BS 7671:2018+A4:2026. The UK rules pack is in beta, and the work itself stays with a registered electrician. Free to start, nothing to install.

BS 7671:2018+A4:2026 · beta

Demo: a studio flat's electrical plan in one minute

Demo video

What the video shows, step by step

  1. We draw the walls of the studio on the grid: a main room, a kitchenette and a shower room. Floor areas appear on their own.
  2. One click on “Equip the rooms” places Circuia’s suggested layout (BS 7671 sets no minimum per room): sockets and a switched lighting point in each room, plus the cooker and appliance outlets in the kitchenette.
  3. In the shower room, zones 0, 1 and 2 are drawn around the tray; a socket dropped too close is flagged straight away.
  4. Automatic wiring groups the points into circuits: a ring or radial for the sockets, a lighting circuit, a dedicated cooker circuit.
  5. The consumer unit fills in: 30 mA RCD protection, circuit breakers, surge protection at the origin.
  6. The check turns green, and the plan, consumer unit schedule, single-line diagram and materials list export as PDFs.

What goes on a studio flat's plan

Example: a 27 m² studio with a main room of about 19 m² (living and sleeping), an open kitchenette and a shower room. In England and Wales BS 7671 sets no minimum number of sockets per room, so Circuia suggests a practical layout and checks how the circuits are built; in Scotland the pack also applies the socket counts of Standard 4.6.

Typical layout of a studio flat in Circuia
RoomPointsCircuit
Main roomDouble sockets around the room, TV and data points, ceiling lightSockets on a ring (B32, 2.5 mm²) or a 20 A radial
KitchenetteWorktop sockets, fridge, cooker or hob, extractorCooker circuit B32 on 6 mm²; appliances above 3 kW on their own circuit
Shower roomNo 230 V socket within 2.5 m of zone 1Lighting and any electric shower behind a 30 mA RCD

Typical circuits in a studio flat

  • Sockets: a ring final circuit B32 on 2.5 mm² serves up to 100 m²; a 20 A radial on 2.5 mm² up to 50 m².
  • Lighting: B6 on 1.5 mm².
  • Cooker: B32 on 6 mm², via a cooker control unit.
  • Immersion heater: B16 on 2.5 mm², never on the ring.
  • RCD protection: 30 mA additional protection for sockets, lighting and everything in the shower room.

Each value comes from the editor's UK rules pack, explained in the BS 7671 guide.

Shower room and kitchenette: what to watch

Shower room: zones 0, 1 and 2 only. Zone 1 rises to 2.25 m above the tray, zone 2 extends 0.6 m beyond it, and 230 V sockets must sit at least 2.5 m horizontally from the boundary of zone 1. Work in a bath or shower location is notifiable in England.

Kitchenette: space is tight, so keep worktop sockets clear of the sink and hob, give the cooker its own circuit and put any appliance above 3 kW on a dedicated circuit rather than on the ring.

Plans

Plans
PlanPriceWho it's forIncluded
Free£0ExplorePlan editor (electrical and plumbing) · Real-time checks against your country's rules · Consumer unit suggested automatically · Up to 3 active projects
Project Pass£35 incl. VATHomeownersPDF export: plan, consumer unit and single-line diagram · Detailed bill of materials · AI assistant included (account required)
Pro£45 excl. VAT / monthElectriciansUnlimited projects · PDF exports with your business details · Bill of materials and quote basis
All prices →

Other use cases

Frequently asked questions

How many sockets does a studio flat need?

In England, Wales and Northern Ireland BS 7671 sets no minimum per room: it limits the floor area each socket circuit serves. Circuia proposes a practical layout; in Scotland it also checks the socket counts of the Technical Handbook (Standard 4.6).

Does every circuit need an RCD?

In a home practically yes: BS 7671 requires 30 mA additional protection for sockets, lighting, cables buried less than 50 mm in walls and all circuits in a bathroom. Circuia places the RCDs and flags any circuit left unprotected.

Is the plan certified or BS 7671 compliant?

No software can promise that. The UK rules pack is in beta: it is built from public sources and has not yet been reviewed by a UK electrician. The installation must be done or checked by a registered electrician, who issues the Electrical Installation Certificate and handles Part P notification where it applies.

Is it free?

Drawing, equipping and checking the plan are free. The Project Pass (£35 incl. VAT, one-off for one home) adds PDF exports and the materials list.

Design aid

Draw your studio flat now

The walls, then one click: Circuia places the points, builds the consumer unit and checks the UK rules as you go.

Draw my plan for free