Skip to content
circuia
Editor

The country sets the standard for new projects and the currency.

Free tool · No sign-up

RCD planner: how many, which type, which circuits (GFCI/AFCI for the US)

Describe the home: the planner wires it with the editor's engine and shows each 30 mA RCD (or RCBO), its type and the circuits behind it, with the reason for each type. For the US, it lists where GFCI and AFCI protection is required (NEC 2023 210.8(A), 210.12(A)).

Updated on BS 7671 · NEC

Inputs

Rules applied: BS 7671:2018+A4:2026 — United Kingdom (beta, IET Wiring Regulations 18th Edition) · beta rules, to be checked locally

m²
Appliances
W

0 = no electric heating

Result

RCBOs

7

Type A / F / B

7

Max circuits / RCD

1

This country's pack wires one circuit per RCD: in practice one RCBO per circuit (or a split-load board).

  1. #1 · 40 A 30 mA type Ageneral circuits (type A minimum)

    • Cooker32 A · 6 mm²
  2. #2 · 40 A 30 mA type Ageneral circuits (type A minimum)

    • Water heater16 A · 2.5 mm²
  3. #3 · 40 A 30 mA type Ageneral circuits (type A minimum)

    • Lighting – living room, kitchen, bathroom +16 A · 1.5 mm²
  4. #4 · 40 A 30 mA type Ageneral circuits (type A minimum)

    • Lighting – hall, bedrooms6 A · 1.5 mm²
  5. #5 · 40 A 30 mA type Ageneral circuits (type A minimum)

    • Sockets – kitchen, bathroom32 A · 2.5 mm²
  6. #6 · 40 A 30 mA type Ageneral circuits (type A minimum)

    • Ventilation6 A · 1.5 mm²
  7. #7 · 40 A 30 mA type A + RDC-DD 6 mAEV charging, own RCD

    • EV charger32 A · 6 mm²
What each RCD type detects
ACACresistive loads only (where still allowed)
AAC · pulsating DCsockets, washer, dishwasher, induction hob
FAC · pulsating DC · mixed frequenciesinverter washer, heat pump, AC (single-phase)
BAC · pulsating DC · mixed frequencies · smooth DCEV chargers, three-phase inverters
A + RDC-DDAC · pulsating DC · 6 mA smooth DCEV charger with built-in DC detection

Split computed by the Circuia wiring engine on a typical home. Have it checked by an electrician.

References

  • § BS 7671 Reg. 411.3.3 (30 mA for sockets ≤ 32 A)
  • § BS 7671 Reg. 411.3.4 (domestic lighting)
  • § BS 7671 Reg. 314.1 / 531.3.3 (avoid unwanted tripping; type A minimum)
  • § BS 7671 Reg. 722.531.3.101 (EV)

Estimate for planning only. Switch off before any work and have it checked by a qualified electrician.

Next step · free

Turn this result into a real plan

Draw your rooms, place sockets and lights: Circuia checks every rule as you go and builds the board schedule.

Open the free editor →Free · no sign-up to start
</> Embed this tool on your website

Free, no sign-up. Paste this code into your page (blog, contractor site, forum): the tool shows up and stays up to date.

How it works

  • Circuits are spread over RCDs with the country's limit per RCD; EV charging gets its own RCD.
  • Type A (or F) for appliances with electronics (washer, dryer, induction hob); type B or A + 6 mA DC detection for EV chargers.
  • UK: socket circuits ≤ 32 A and cables in walls need 30 mA RCDs (BS 7671 411.3.3, 522.6.202).
  • US: GFCI by location (210.8(A)), AFCI for 120 V 15/20 A circuits in living areas (210.12(A)).

Frequently asked questions

What is the difference between RCD types AC, A, F and B?

Type AC detects AC leakage only; type A also pulsating DC (electronics); type F adds mixed frequencies (inverter appliances); type B also smooth DC (EV chargers, three-phase inverters).

Where is GFCI required in a US home?

NEC 2023: bathrooms, kitchens, garages, outdoors, basements, crawl spaces, laundry areas, within 6 ft of sinks, boathouses and the dishwasher outlet.

Can I use type AC RCDs?

Some countries still allow type AC for purely resistive circuits; the UK and many others now require type A as a minimum. The planner follows the selected country.

Design aid

For your actual home, move to the editor

Draw your home or describe it to the AI: Circuia places the points, checks the rules in real time and generates the consumer unit, single-line diagram and bill of materials.