Free tool · No sign-up
RCD planner: how many, which type, which circuits (GFCI/AFCI for the US)
Describe the home: the planner wires it with the editor's engine and shows each 30 mA RCD (or RCBO), its type and the circuits behind it, with the reason for each type. For the US, it lists where GFCI and AFCI protection is required (NEC 2023 210.8(A), 210.12(A)).
Updated on BS 7671 · NEC
Result
RCBOs
7
Type A / F / B
7
Max circuits / RCD
1
This country's pack wires one circuit per RCD: in practice one RCBO per circuit (or a split-load board).
#1 · 40 A 30 mA type Ageneral circuits (type A minimum)
- Cooker32 A · 6 mm²
#2 · 40 A 30 mA type Ageneral circuits (type A minimum)
- Water heater16 A · 2.5 mm²
#3 · 40 A 30 mA type Ageneral circuits (type A minimum)
- Lighting – living room, kitchen, bathroom +16 A · 1.5 mm²
#4 · 40 A 30 mA type Ageneral circuits (type A minimum)
- Lighting – hall, bedrooms6 A · 1.5 mm²
#5 · 40 A 30 mA type Ageneral circuits (type A minimum)
- Sockets – kitchen, bathroom32 A · 2.5 mm²
#6 · 40 A 30 mA type Ageneral circuits (type A minimum)
- Ventilation6 A · 1.5 mm²
#7 · 40 A 30 mA type A + RDC-DD 6 mAEV charging, own RCD
- EV charger32 A · 6 mm²
What each RCD type detects
| AC | AC | resistive loads only (where still allowed) |
|---|---|---|
| A | AC · pulsating DC | sockets, washer, dishwasher, induction hob |
| F | AC · pulsating DC · mixed frequencies | inverter washer, heat pump, AC (single-phase) |
| B | AC · pulsating DC · mixed frequencies · smooth DC | EV chargers, three-phase inverters |
| A + RDC-DD | AC · pulsating DC · 6 mA smooth DC | EV charger with built-in DC detection |
Split computed by the Circuia wiring engine on a typical home. Have it checked by an electrician.
References
- § BS 7671 Reg. 411.3.3 (30 mA for sockets ≤ 32 A)
- § BS 7671 Reg. 411.3.4 (domestic lighting)
- § BS 7671 Reg. 314.1 / 531.3.3 (avoid unwanted tripping; type A minimum)
- § BS 7671 Reg. 722.531.3.101 (EV)
Estimate for planning only. Switch off before any work and have it checked by a qualified electrician.
Next step · free
Turn this result into a real plan
Draw your rooms, place sockets and lights: Circuia checks every rule as you go and builds the board schedule.
</> Embed this tool on your website
Free, no sign-up. Paste this code into your page (blog, contractor site, forum): the tool shows up and stays up to date.
How it works
- Circuits are spread over RCDs with the country's limit per RCD; EV charging gets its own RCD.
- Type A (or F) for appliances with electronics (washer, dryer, induction hob); type B or A + 6 mA DC detection for EV chargers.
- UK: socket circuits ≤ 32 A and cables in walls need 30 mA RCDs (BS 7671 411.3.3, 522.6.202).
- US: GFCI by location (210.8(A)), AFCI for 120 V 15/20 A circuits in living areas (210.12(A)).
Frequently asked questions
What is the difference between RCD types AC, A, F and B?
Where is GFCI required in a US home?
Can I use type AC RCDs?
Design aid
For your actual home, move to the editor
Draw your home or describe it to the AI: Circuia places the points, checks the rules in real time and generates the consumer unit, single-line diagram and bill of materials.
Other free tools
- Free toolCable size calculatorPower, length, use → cable size and breaker (mm² or AWG).
- Free toolSockets per roomRoom type + area → minimum sockets, lights, data points.
- Free toolConsumer unit plannerYour home → RCDs, breakers, rows of the panel.
- Free toolSupply capacity calculatorYour appliances → subscription, main fuse or service size.
- Free toolVoltage drop calculatorSize, length, current → % drop, within the limit or not.
- Free toolSingle-line diagram generatorYour home → printable single-line diagram of the panel.