Bathroom electrical zones: what is allowed where?

Click a zone of the drawing: the tool shows what can be installed there and the IP rating it needs — BS 7671 zones 0, 1 and 2 in the UK, the HD 60364-7-701 zones elsewhere in Europe, and the 3 ft / 8 ft clearances of the NEC in the US.

Updated on BS 7671 · NEC

Inputs

Rules applied: BS 7671:2018+A4:2026 — United Kingdom (beta, IET Wiring Regulations 18th Edition) · beta rules, to be checked locally

Fixture

Click a zone of the drawing.

Zone 0Zone 1Zone 2Outside the zonessockets allowed from here
  • Zone 1 height: 2.25 m
  • Zone 2 width: 0.6 m
  • Sockets from zone 1: 3 m

Result

Zone 1

Above zone 0 up to 2.25 m from the floor.

EquipmentAllowed?IP
Socket outlet✕ not allowed—
Shaver socket✕ not allowed—
SwitchSELV SELV 12 V onlyIPX4
Light fitting✓ allowedIPX4
Extractor fan✓ allowedIPX4
Heated towel rail✓ allowedIPX4
Water heater✓ allowedIPX4
Electric shower / pump✓ allowedIPX5 where water jets are used for cleaning.IPX4
Washing machine✕ not allowed—
Under-floor heating! under conditionsUnder-floor heating with a metal grid or sheath connected to the protective conductor, 30 mA RCD.—

Simplified summary. National deviations and manufacturers' instructions apply; have the bathroom checked by an electrician.

References

  • § BS 7671 Section 701 (701.32, 701.512.3)
  • § BS 7671 Reg. 701.411.3.3 (30 mA RCD)

Estimate for planning only. Switch off before any work and have it checked by a qualified electrician.

Next step · free

Turn this result into a real plan

Open the editor with a bathroom already drawn: Circuia flags any socket or light placed in the wrong zone.

Open the editor with this result →Free · no sign-up to start
</> Embed this tool on your website

Free, no sign-up. Paste this code into your page (blog, contractor site, forum): the tool shows up and stays up to date.

How it works

  • Zone 0 is inside the bath or shower tray; zone 1 above it up to 2.25 m; zone 2 extends 0.6 m beyond zone 1 (BS 7671 701.32).
  • Walk-in showers without a tray: zone 1 extends 1.2 m from the fixed water outlet.
  • UK: ordinary sockets at least 3 m from zone 1 (701.512.3); all circuits of the bathroom on a 30 mA RCD (701.411.3.3).
  • US: no receptacle within 3 ft horizontally / 8 ft vertically of the tub or shower (406.9(C)); all bathroom receptacles GFCI (210.8(A)(1)).

Frequently asked questions

Can I have a socket in a UK bathroom?

Yes, if it is at least 3 m horizontally from the boundary of zone 1 and on a 30 mA RCD. Shaver supply units are allowed in zone 2.

What IP rating for bathroom lights?

At least IPX4 in zones 1 and 2 (IPX5 where water jets are used), IPX7 for SELV fittings in zone 0.

How far must a receptacle be from a bathtub in the US?

Not within 3 ft horizontally and 8 ft vertically of the tub rim or shower threshold (NEC 406.9(C)), and GFCI-protected.

Design aid

For your actual home, move to the editor

Draw your home or describe it to the AI: Circuia places the points, checks the rules in real time and generates the consumer unit, single-line diagram and bill of materials.

Open the free editor