Standard · New Zealand
AS/NZS 3000 in New Zealand: the 2018 Wiring Rules, mandatory from 13 November 2026
AS/NZS 3000, the Wiring Rules, is the standard every electrical installation in New Zealand must meet. The 2018 edition with Amendments 1, 2 and 3 replaced the 2007 edition in the Electricity (Safety) Regulations 2010 and is the only cited edition for new work from 13 November 2026. For a house, that means 30 mA RCDs of type A, F or B on socket-outlet and lighting circuits, testing to Section 8, and a Certificate of Compliance for every fixed-wiring job.
Updated on Last checked AS/NZS 3000:2018 + A1–A3 · beta
Key facts
- 01From 13 November 2025 to 13 November 2026, electrical workers could use AS/NZS 3000:2007 (Amendments 1 and 2) or AS/NZS 3000:2018 (Amendments 1, 2 and 3); from 13 November 2026 new work must use the 2018 edition (WorkSafe NZ).
- 02Every Certificate of Compliance (CoC) must name the edition used, year and amendments included.
- 03Homes need 30 mA RCD protection on socket-outlet, lighting and hand-held equipment circuits; new RCDs must be type A, F or B — type AC is no longer enough for new work.
- 04The Australian rule of at most 3 final subcircuits per RCD is Australia-only; it is still good practice to spread circuits over at least 2 RCDs.
- 05Fixed wiring is prescribed electrical work for a licensed electrician; homeowners may only do limited work under regulation 57, inspected before connection.
What is AS/NZS 3000 and why does it matter in New Zealand?
AS/NZS 3000, “Electrical installations (known as the Australian/New Zealand Wiring Rules)”, is a joint standard published by Standards Australia and Standards New Zealand. It sets how low-voltage installations are designed, built and tested: protection against electric shock and overcurrent, cable selection, switchboards, earthing, wet areas and verification. Australia and New Zealand share the same document, with clauses marked “Australia only” or “New Zealand only” where the two countries differ.
In New Zealand the standard is not voluntary. The Electricity (Safety) Regulations 2010 cite AS/NZS 3000 in Schedule 2, and an installation built to the cited edition is deemed to comply with the fundamental safety principles of the regulations. The regulator is WorkSafe New Zealand; the Electrical Workers Registration Board (EWRB) licenses the people allowed to do the work.
The paperwork depends on the type of work, not just on the standard: a Certificate of Compliance for most fixed wiring, an Electrical Safety Certificate when an installation is connected, and a Record of Inspection for high-risk work. All of these name the edition of AS/NZS 3000 that was used.
The switch to AS/NZS 3000:2018 on 13 November 2026
For more than a decade New Zealand kept citing AS/NZS 3000:2007 with Amendments 1 and 2, while Australia moved to the 2018 edition in 2019. The Electricity (Safety) Amendment Regulations 2025 changed Schedule 2: from 13 November 2025 electrical workers could choose either edition, and from 13 November 2026 new work must use AS/NZS 3000:2018 including Amendments 1, 2 and 3.
| Period | Edition for new work | Source |
|---|---|---|
| Before 13 November 2025 | AS/NZS 3000:2007 + A1 + A2 | Electricity (Safety) Regulations 2010, Schedule 2 |
| 13 November 2025 to 13 November 2026 | Either the 2007 edition (+ A1, A2) or the 2018 edition (+ A1, A2, A3) | Electricity (Safety) Amendment Regulations 2025, WorkSafe NZ |
| From 13 November 2026 | AS/NZS 3000:2018 + A1 + A2 + A3 | WorkSafe NZ |
The change does not force anyone to upgrade an existing installation: maintenance and replacement can still follow the rules the installation was built to, as allowed by regulation 59. What changes is the reference for new work, alterations and additions, and the wording of the certificates. New Zealand also modified a few clauses of the 2018 edition through Schedule 2, notably on RCD types and on switching the neutral; electricians should work from the cited text with those modifications.
RCDs in a New Zealand home
RCDs (residual current devices, often combined with the circuit-breaker as an RCBO) are the main protection against electric shock in a home. According to trade summaries of the 2018 edition, residential socket-outlet, lighting and hand-held equipment circuits need 30 mA RCD protection in New Zealand (clause 2.6.3.3.1). The Australian clause that extends the requirement to every final subcircuit, hard-wired cooktop and hot water cylinder included, is marked “Australia only”.
| Rule | New Zealand | Australia |
|---|---|---|
| Circuits needing a 30 mA RCD | Socket-outlet, lighting and hand-held equipment circuits (cl. 2.6.3.3.1) | Every final subcircuit of a home (cl. 2.6.3.2.2) |
| RCD type | Type A, F or B for new work; RCDs open active and neutral (cl. 2.6.2.2.3, as modified) | Type AC banned in new work since 1 May 2023 |
| Circuits per RCD | No limit found; Circuia keeps 3 as good practice | At most 3 final subcircuits per RCD |
| Number of RCDs | Good practice: at least 2, lighting split between them | At least 2 when there is more than one final subcircuit |
| Testing | Every RCD tested with an instrument, not only the test button | Operating time and current recorded |
Why spread the circuits? If the whole house sits behind one RCD, a single fault in an outdoor socket-outlet or a damp appliance cuts the lights everywhere, at night. Circuia's auto-wiring therefore puts every circuit behind a type A 30 mA RCD, at most 3 circuits per RCD, with the lighting circuits on different RCDs. In New Zealand these are flagged as information, not errors, because they are good practice rather than a New Zealand clause.
Arc fault detection devices (AFDDs) have their own New Zealand clause (2.9.7), which requires them on final subcircuits up to 20 A in some fire-risk locations. Ordinary bedrooms are not among the places reported by the trade summaries, so Circuia only suggests considering an AFDD on bedroom socket-outlet circuits.
Circuits, cables and the switchboard
Most New Zealand houses have a single-phase 230 V, 50 Hz supply, typically protected by a 60 A service fuse, with MEN earthing (multiple earthed neutral): the neutral and earth are linked at the main switchboard, with a main earthing conductor to an electrode. Larger homes and some rural properties have a three-phase supply. Your lines company's connection rules set the details.
| Circuit | Breaker | Copper TPS cable | Note |
|---|---|---|---|
| Lighting | 10 A | 1.5 mm² | 1.5 mm² protected at 16 A at most |
| Socket-outlets (power points) | 20 A | 2.5 mm² | 2.5 mm² protected at 20 A at most |
| Cooktop or range | 32 A | 6 mm² | Isolating switch nearby |
| Hot water cylinder | 20 A | 2.5 mm² | Isolating switch adjacent; often on a controlled (ripple) tariff |
| Heat pump | 20 A | 2.5 mm² | Isolator next to the outdoor unit; check the nameplate |
| EV charger | 32 A | 6 mm² | Dedicated circuit and RCD, DC fault detection |
AS/NZS 3000 limits the voltage drop to 5 % from the point of supply to any point of the installation (clause 3.6). Circuia estimates it per circuit from the cable route drawn on the plan and suggests the next cable size when a long run goes over the limit.
Bathrooms, laundries and kitchens
Section 6 of AS/NZS 3000 divides bathrooms and showers into zones. No socket-outlet is allowed in zones 0 and 1; zone 2 extends 0.6 m beyond the bath or shower up to 2.25 m, where only a shaver outlet or an RCD-protected socket-outlet inside a cupboard is accepted, and no socket-outlet may be within 0.3 m in zone 3. Circuia flags points drawn too close to a bath or shower.
In the kitchen, no socket-outlet or light switch should sit within 150 mm of the cooktop, and a fixed cooktop needs an isolating switch within 2 m, not on the appliance itself. Circuia reminds you of these when a cooktop is placed.
Certificate of Compliance, ESC and Record of Inspection
Prescribed electrical work is classified by risk under the Electricity (Safety) Regulations 2010, and the category decides the paperwork. The electrician who did or supervised the work issues the Certificate of Compliance (CoC) after testing; the person who connects the installation to the supply issues the Electrical Safety Certificate (ESC), which confirms that it is safe to use. High-risk work must also be inspected by a licensed electrical inspector, who issues a Record of Inspection, and it is entered in WorkSafe's high-risk database.
| Category | Examples | Certificates |
|---|---|---|
| Low risk | Like-for-like replacement of fittings | Electrical Safety Certificate |
| General | New circuits, an extension, a new house | Certificate of Compliance + Electrical Safety Certificate |
| High risk | Mains work, work on some special installations, homeowner work that needs certification | Certificate of Compliance + Record of Inspection + Electrical Safety Certificate |
Testing follows Section 8 of AS/NZS 3000: continuity of the earthing conductors, insulation resistance, polarity, correct circuit connections, earth fault-loop impedance and RCD operation. New Zealand asks for every RCD to be tested with an instrument (trip time and current), not just with its test button.
Can you do your own electrical work in New Zealand?
Only a little. The law lets a homeowner do a limited amount of electrical wiring work in a home they own and live in, under regulation 57 of the Electricity (Safety) Regulations 2010 and the code of practice NZECP 51. The finished work must be tested and connected by a licensed electrical inspector, who checks that it is safe before it is energised. Work on the main switchboard, the mains and the main earth is reserved for licensed people.
Planning an AS/NZS 3000:2018 installation with Circuia
Choose New Zealand when you create the project. The editor uses 230 V single-phase with MEN earthing, sizes lighting at 10 A on 1.5 mm², socket-outlets at 20 A on 2.5 mm² and the cooktop at 32 A on 6 mm², puts every circuit behind a type A 30 mA RCD (at most 3 per RCD), flags type AC RCDs and socket-outlet or lighting circuits without RCD protection, and reminds you of the CoC and ESC. The circuit schedule, single-line diagram and bill of materials (AS/NZS 3112 outlets, TPS cable) follow. Read more on the New Zealand electrical plan software page.
| Plan | Price | What you get |
|---|---|---|
| Free | NZ$0 | Plan editor, live AS/NZS 3000 check (beta), automatic circuits, up to 3 active projects |
| Project Pass | NZ$75 incl. GST, one-off | PDF exports, materials list, testing checklist |
| Pro | NZ$95 a month or NZ$950 a year, excl. GST | Unlimited projects, PDFs with your NZBN |
| Team | NZ$239 a month or NZ$2,390 a year, excl. GST | Shared projects; extra seat NZ$59 a month |
Open the editor set up for New Zealand (free, in your browser), compare with other countries' standards or see all prices.
Common mistakes
- Writing “AS/NZS 3000:2007” on a Certificate of Compliance for new work started after 13 November 2026.
- Fitting type AC RCDs in new work: New Zealand now expects type A, F or B.
- Putting the whole house behind one RCD, so one fault leaves every room in the dark.
- Assuming the Australian rules apply unchanged: RCDs on every circuit and three circuits per RCD are Australia-only clauses.
- Energising homeowner wiring before a licensed electrical inspector has checked and connected it.
- Fitting a socket-outlet or light switch within 150 mm of the cooktop.
Frequently asked questions
When did AS/NZS 3000:2018 become mandatory in New Zealand?
Is AS/NZS 3000 the same in Australia and New Zealand?
Do I need a Certificate of Compliance for new wiring?
What is the difference between a CoC and an ESC?
Is AS/NZS 3000 available as a free PDF?
How much does Circuia cost in New Zealand?
Does Circuia certify an installation to AS/NZS 3000?
Design aid
Design the installation with this country's rules
Draw the home or describe it to the AI: Circuia places the points, checks the country's rules in real time and generates the consumer unit, single-line diagram and bill of materials.
Written by
Circuia team
Written by the Circuia team from the sources listed and from the editor's rules pack for this country: the values in the tables are the ones Circuia uses.
Published · updated
Sources
Sources used for this page, official texts first:
- WorkSafe NZ — changes to electricity safety regulations for electrical installations
- Electricity (Safety) Amendment Regulations 2025
- Electricity (Safety) Regulations 2010
- WorkSafe NZ — risk categories and certification of prescribed electrical work
- WorkSafe NZ — doing your own electrical work
- eCertify — AS/NZS 3000 Section 2 changes
- Qualtec — RCD types A, F and B in New Zealand from November 2026
Related pages
- OverviewElectrical wiring codes and standards: US NEC, UK, Ireland, NordicsHome wiring rules explained: the US NEC 2023, the UK's BS 7671, Ireland, Norway, Sweden, Denmark and Finland, with the Circuia editor for each.
- CircuiaElectrical plan software for New ZealandDraw house electrical plans online: circuits, RCDs and switchboard checked against AS/NZS 3000:2018 + A1–A3, prices in NZD. New Zealand pack in beta.
- GuideBS 7671 explained: the UK wiring regulations for homes (18th Edition, A4:2026)BS 7671:2018+A4:2026: what Amendment 4 changed, plus ring, radial, RCD and bathroom rules for homes. Printable summary and a free sample plan to UK rules.
- CircuiaPricing: free, Project Pass €29, Pro €49/monthCircuia plans: Free to explore, Project Pass at €29 incl. VAT for a homeowner project, Pro at €49 excl. VAT/month and Team at €129 excl. VAT/month for electricians. 14-day trial.
- CircuiaCircuia: AI wiring plans to BS 7671 and EU standardsDraw your home or ask the AI: Circuia designs circuits and the consumer unit, checked against BS 7671, I.S. 10101 and the rules of 17 European countries.