Software · New Zealand
Circuia draws the electrical plan of a house or unit in your browser: you sketch the rooms, place power points, lights and appliances, and it builds the final subcircuits, the 30 mA RCDs, the switchboard and a bill of materials. The New Zealand pack checks AS/NZS 3000:2018 + A1–A3, cited from 13 November 2026; it is in beta. Testing and the Certificate of Compliance stay with the licensed electrician.
Last checked AS/NZS 3000:2018 + A1–A3 · beta
01
Plan, circuit schedule, switchboard layout and materials list come out of one project. The PDF carries your logo, address and NZBN, ready for the client, the builder or the inspector.
02
A clear electrical layout to IEC 60617 symbols, with circuits and RCDs already worked out: a solid base for pricing, for the consent drawings and for coordinating with the electrician on site.
03
Decide where the power points, lights, heat pump and EV charger go before the work starts, then ask for quotes on a concrete plan. The wiring itself is prescribed electrical work for a licensed electrician; homeowner work is limited to what regulation 57 allows.
Sketch the walls on the grid or trace over an existing floor plan (image or PDF). Room areas are calculated as you go.
Double power points, lights, switches, cooktop, hot water cylinder, heat pump and EV charger: with the mouse, or by asking the AI assistant.
Auto-wiring builds the final subcircuits and puts them behind type A 30 mA RCDs, never more than 3 per RCD. The New Zealand rules run live and often offer a one-click fix.
Plan, circuit schedule, single-line diagram, materials list and a testing checklist as PDF for the client, the builder or the inspector (from the Project Pass).
01
Lighting 10 A on 1.5 mm², socket-outlets 20 A on 2.5 mm², cooktop and EV charger 32 A on 6 mm², with the breaker checked against the cable size (1.5 mm² up to 16 A, 2.5 mm² up to 20 A).
02
Type A 30 mA RCD protection on socket-outlet, lighting and bathroom circuits, type AC flagged for new work, circuits spread over at least 2 RCDs so one trip does not black out the house.
03
Switchboard layout with rows and spare ways, single-phase 230 V supply (60 A service typical), MEN earthing noted, three-phase available for larger homes.
04
AS/NZS 3112 socket-outlets, TPS twin & earth cable, single-pole MCBs, RCDs or RCBOs: a base for your quote and your order at the wholesaler.
05
Circuit schedule and a testing checklist (continuity, insulation resistance, polarity, fault-loop impedance, RCD trip times) to support the Certificate of Compliance. Results and signatures stay with the electrician.
06
With Pro, every PDF carries your logo, address and New Zealand Business Number (NZBN, 13 digits).
Circuia checks a house plan against the values explained in the AS/NZS 3000 New Zealand guide. The table shows an extract, with the values the editor uses. AS/NZS 3000 sets no minimum number of socket-outlets per room: Circuia only makes comfort suggestions there.
| Topic | Reference | What is flagged |
|---|---|---|
| Cable and breaker | AS/NZS 3000 cl. 2.5.3 | Breaker too large for the cable (1.5 mm² above 16 A, 2.5 mm² above 20 A) |
| RCD on socket-outlets | AS/NZS 3000 cl. 2.6.3.3.1 | Socket-outlet circuit without a 30 mA RCD |
| RCD on lighting | AS/NZS 3000 cl. 2.6.3.3.1 | Lighting circuit without a 30 mA RCD |
| RCD type | AS/NZS 3000 cl. 2.6.2.2.3 | Type AC RCD in new work (type A, F or B needed) |
| Spread of circuits | Good practice | Whole house on one RCD, more than 3 circuits on one RCD (information) |
| Wet areas | AS/NZS 3000 §6.2 | Socket-outlet or switch within 0.6 m of the shower or bath (zones 0 to 2) |
| Cooktop | AS/NZS 3000 cl. 4.7 | Socket-outlet or light switch within 150 mm, isolating switch reminder |
| EV charger | AS/NZS 3000 Appendix P | Shared circuit or RCD, undersized circuit, DC fault detection |
| Voltage drop | AS/NZS 3000 cl. 3.6 | More than 5 % on the estimated cable route |
| Certification | Electricity (Safety) Regulations 2010 | Reminder: CoC, ESC on connection, Record of Inspection for high-risk work |
The Electricity (Safety) Amendment Regulations 2025 replaced AS/NZS 3000:2007 with AS/NZS 3000:2018 including Amendments 1, 2 and 3 in Schedule 2 of the Electricity (Safety) Regulations 2010. From 13 November 2025 electrical workers could use either edition; from 13 November 2026 new work must follow the 2018 edition, and every Certificate of Compliance must name it, year and amendments included (WorkSafe NZ).
Existing installations do not have to be upgraded because the cited edition changed. Circuia's New Zealand pack is written for new work and alterations to the 2018 edition.
Fixed wiring is prescribed electrical work: a licensed electrical worker does it, tests it and issues a Certificate of Compliance (CoC). When the installation is connected to the supply, an Electrical Safety Certificate (ESC) confirms it is safe to use. High-risk work, such as work on mains or homeowner wiring, also needs a licensed electrical inspector's Record of Inspection before connection.
Homeowners may do a limited amount of wiring in their own home under regulation 57 and NZECP 51, but the work must be inspected and connected by a licensed electrical inspector. Circuia prepares the plan and the circuit schedule; it issues no certificate.
| Type of work | Certificates |
|---|---|
| Low-risk work | Electrical Safety Certificate |
| General work (e.g. new circuits, a new house) | Certificate of Compliance + Electrical Safety Certificate |
| High-risk work (e.g. mains, homeowner work) | Certificate of Compliance + Record of Inspection + Electrical Safety Certificate |
| Need | CAD, spreadsheet, templates | Circuia |
|---|---|---|
| IEC 60617 symbols | Libraries to assemble | Built in |
| AS/NZS 3000:2018 checks | By hand, Wiring Rules open | Live (beta) |
| Circuits and RCD grouping | By hand | Proposed automatically |
| Switchboard and single-line diagram | Drawn separately | Generated from the plan |
| Materials list with AS/NZS 3112 outlets, TPS, RCBOs | By hand | Generated |
| Circuit schedule and testing checklist | Retyped | Prepared |
| Plan | Price | For | Included |
|---|---|---|---|
| Free | $0 | Explore | Plan editor, live AS/NZS 3000 check (beta), automatic circuits and switchboard, up to 3 active projects |
| Project Pass | $75 incl. GST | Homeowners | PDF export (plan, switchboard, single-line diagram), materials list, testing checklist for the CoC, AI assistant (account required) |
| Pro | $95 excl. GST / month | Electricians | Unlimited projects, PDFs with your details and NZBN, materials list as a quote base, AI assistant |
Design aid
Design the installation with this country's rules
Draw the home or describe it to the AI: Circuia places the points, checks the country's rules in real time and generates the consumer unit, single-line diagram and bill of materials.